High continuous load
At this power level a normal household outlet should not be assumed suitable. Ask a qualified electrician to assess sanctioned load, cable size, breaker rating, earthing and connector temperature under continuous operation.
Bitmain
Standard Model
Est. Daily Income
Calculating...
Based on Live BTC
Hashrate
16000
MH/sPower
3360W
ConsumptionMonthly
2419
Units (kWh)Catalogue Price
₹3,70,000
*Confirm live price, GST treatment and stock
Exact listing profile
These fields come from the current XYZ Mining Shop catalogue. Confirm the offered machine’s label and measured values before purchase.
Hashrate
16 GH/s
Algorithm
Scrypt
Power
3,360W
Cooling
Air
Monthly energy
2,419.2 kWh
Catalogue status
Catalogue listing available
Model decision
The operating case begins with 16 GH/s and 3,360W. It suits a prepared Scrypt deployment comparing Litecoin/Dogecoin merged-mining output against electricity and ventilation cost.
At this power level a normal household outlet should not be assumed suitable. Ask a qualified electrician to assess sanctioned load, cable size, breaker rating, earthing and connector temperature under continuous operation.
At the listed 3,360W, continuous operation is approximately 2,419.2 kWh per 30-day month before cooling overhead. Nominal current is about 14.61A at 230V, and the room or liquid loop must reject roughly 11,464.32 BTU/hour of heat. Actual wall draw varies by batch, firmware, voltage and ambient conditions.
Plan a clean intake and a direct hot-air exhaust so discharged heat cannot recirculate. Fan noise and airflow rise with ambient temperature; choose the room and ducting before delivery.
For a Bitmain quotation, match the complete Antminer model, hashrate bin, serial and cooling version. Family names alone are not enough because adjacent variants can use different operating profiles.
Using the catalogue figures, the simple power-to-hash ratio is about 210 W per GH/s. Use this only to compare machines working on the same Scrypt workload.
Model-specific worksheet
This worksheet converts Antminer L9 (16G) from a product name into auditable inputs. The current entry is 16 GH/s and 3,360W; within its algorithm group it occupies hashrate position 8 of 11. Against Antminer L9 (15G), this listing provides 6.67% more hashrate with 0W more nominal power and a ₹20,000 higher catalogue price. Antminer L9 (17G), the next higher-hashrate entry, adds 6.25% hashrate while changing nominal power by 0W upward; its catalogue price is ₹20,000 higher.
Catalogue rank
8 of 11 by hashrate
Price intensity
₹23,125 per GH/s
Efficiency input
210 W/GH/s
24-hour energy
80.64 kWh
The machine converts almost all consumed electrical power into heat. The listed draw corresponds to roughly 11,464.32 BTU/hour per unit, or 34,392.96 BTU/hour for three. A air deployment must reject that heat without returning it to the intake or coolant loop.
| Fleet | Nominal load | 30-day energy | Current at 230V* | Heat output |
|---|---|---|---|---|
| 1 unit | 3.36kW | 2,419.2 kWh | 14.61A | 11,464.32 BTU/h |
| 3 units | 10.08kW | 7,257.6 kWh | 43.83A | 34,392.96 BTU/h |
| 5 units | 16.8kW | 12,096 kWh | 73.04A | 57,321.6 BTU/h |
| All-in tariff | 1 unit/month | 3 units/month | 5 units/month |
|---|---|---|---|
| ₹4/kWh | ₹9,677 | ₹29,030 | ₹48,384 |
| ₹6/kWh | ₹14,515 | ₹43,546 | ₹72,576 |
| ₹8/kWh | ₹19,354 | ₹58,061 | ₹96,768 |
| ₹10/kWh | ₹24,192 | ₹72,576 | ₹1,20,960 |
Use these checks for this quotation instead of relying on copied family specifications.
*Current is simple watts ÷ 230V arithmetic. It is not electrical-design advice and does not include power factor, inrush, derating or cooling auxiliaries.
Purchase check
Range position
This model’s real benchmark is its nearest same-algorithm alternatives. Antminer L9 (15G) sits below it at 15 GH/s, while Antminer L9 (17G) is the next higher comparison at 17 GH/s. Compare ₹/unit sensitivity and cooling cost across all three before choosing a bin.
| Model | Hashrate | Power | Catalogue position |
|---|---|---|---|
| Antminer L9 (15G) | 15 GH/s | 3,360W | ₹3,50,000 |
| Antminer L9 (16G) | 16 GH/s | 3,360W | ₹3,70,000 |
| Antminer L9 (17G) | 17 GH/s | 3,360W | ₹3,90,000 |
Model-specific answers
Each answer is tied to this model’s catalogue position, calculated load or verification path.
Against Antminer L9 (15G), this listing provides 6.67% more hashrate with 0W more nominal power and a ₹20,000 higher catalogue price. Antminer L9 (17G), the next higher-hashrate entry, adds 6.25% hashrate while changing nominal power by 0W upward; its catalogue price is ₹20,000 higher.
The written quote should identify the complete model, 16 GH/s bin, condition, included power or cooling hardware, warranty status, GST treatment and delivery timing.
Not by raw hashrate. Units such as TH/s, GH/s, MH/s and KSol/s describe different workloads. Compare Antminer L9 (16G) only inside the Scrypt group.
At 3,360W, a 24-hour arithmetic estimate is 80.64 kWh before external cooling. Compare this against the meter after commissioning.
Catalogue power divided by catalogue hashrate is approximately 210 W/GH/s. It is a same-algorithm comparison input and not a guaranteed measured result.
Same-algorithm options
15 GH/s · 3,360W
View product →17 GH/s · 3,360W
View product →14 GH/s · 3,500W
View product →Mining income is variable and is not guaranteed. Verify network data, electricity tariff, pool terms, product condition, specifications and the dated quotation independently.
MODEL-SPECIFIC PLANNING WORKSHEET · XY-ANTMINER-L9-16G
The worksheet below is built from this product entry. It exposes each assumption so a buyer can replace catalogue inputs with quotation and meter evidence instead of treating estimates as guarantees.
XY-ANTMINER-L9-16G identity
Worksheet XY-ANTMINER-L9-16G applies only to Antminer L9 (16G), the 16 GH/s Scrypt entry shown on this page. Its calculations begin with 3,360W catalogue input and air cooling; they must be replaced by a dated meter reading if the delivered batch behaves differently.
XY-ANTMINER-L9-16G commercial boundary
The displayed Bitmain hardware figure is ₹3,70,000. Reference XY-ANTMINER-L9-16G keeps that acquisition amount separate from GST treatment, freight, wiring, external heat rejection, pool fees and service work, all of which depend on the quotation or receiving site.
XY-ANTMINER-L9-16G calculation boundary
Every XY-ANTMINER-L9-16G value below is arithmetic, not a profitability forecast or electrical-design instruction. A qualified electrician must size conductors and protection for the complete installation, and network output must be evaluated with current third-party data.
Reference series XY-ANTMINER-L9-16G-T holds 80.64 kWh per day constant and changes only the electricity tariff. The 95% column is a sensitivity case, not promised availability.
| Worksheet ref. | Tariff | Nominal daily energy | Daily electricity | 30-day electricity | 30-day at 95% |
|---|---|---|---|---|---|
| XY-ANTMINER-L9-16G-T01 | ₹4.25/kWh | 80.64 kWh | ₹343 | ₹10,282 | ₹9,768 |
| XY-ANTMINER-L9-16G-T02 | ₹4.50/kWh | 80.64 kWh | ₹363 | ₹10,886 | ₹10,342 |
| XY-ANTMINER-L9-16G-T03 | ₹4.75/kWh | 80.64 kWh | ₹383 | ₹11,491 | ₹10,917 |
| XY-ANTMINER-L9-16G-T04 | ₹5.00/kWh | 80.64 kWh | ₹403 | ₹12,096 | ₹11,491 |
| XY-ANTMINER-L9-16G-T05 | ₹5.25/kWh | 80.64 kWh | ₹423 | ₹12,701 | ₹12,066 |
| XY-ANTMINER-L9-16G-T06 | ₹5.50/kWh | 80.64 kWh | ₹444 | ₹13,306 | ₹12,640 |
| XY-ANTMINER-L9-16G-T07 | ₹5.75/kWh | 80.64 kWh | ₹464 | ₹13,910 | ₹13,215 |
| XY-ANTMINER-L9-16G-T08 | ₹6.00/kWh | 80.64 kWh | ₹484 | ₹14,515 | ₹13,789 |
| XY-ANTMINER-L9-16G-T09 | ₹6.25/kWh | 80.64 kWh | ₹504 | ₹15,120 | ₹14,364 |
| XY-ANTMINER-L9-16G-T10 | ₹6.50/kWh | 80.64 kWh | ₹524 | ₹15,725 | ₹14,939 |
| XY-ANTMINER-L9-16G-T11 | ₹6.75/kWh | 80.64 kWh | ₹544 | ₹16,330 | ₹15,513 |
| XY-ANTMINER-L9-16G-T12 | ₹7.00/kWh | 80.64 kWh | ₹564 | ₹16,934 | ₹16,088 |
| XY-ANTMINER-L9-16G-T13 | ₹7.25/kWh | 80.64 kWh | ₹585 | ₹17,539 | ₹16,662 |
| XY-ANTMINER-L9-16G-T14 | ₹7.50/kWh | 80.64 kWh | ₹605 | ₹18,144 | ₹17,237 |
| XY-ANTMINER-L9-16G-T15 | ₹7.75/kWh | 80.64 kWh | ₹625 | ₹18,749 | ₹17,811 |
| XY-ANTMINER-L9-16G-T16 | ₹8.00/kWh | 80.64 kWh | ₹645 | ₹19,354 | ₹18,386 |
| XY-ANTMINER-L9-16G-T17 | ₹8.25/kWh | 80.64 kWh | ₹665 | ₹19,958 | ₹18,960 |
| XY-ANTMINER-L9-16G-T18 | ₹8.50/kWh | 80.64 kWh | ₹685 | ₹20,563 | ₹19,535 |
| XY-ANTMINER-L9-16G-T19 | ₹8.75/kWh | 80.64 kWh | ₹706 | ₹21,168 | ₹20,110 |
| XY-ANTMINER-L9-16G-T20 | ₹9.00/kWh | 80.64 kWh | ₹726 | ₹21,773 | ₹20,684 |
| XY-ANTMINER-L9-16G-T21 | ₹9.25/kWh | 80.64 kWh | ₹746 | ₹22,378 | ₹21,259 |
| XY-ANTMINER-L9-16G-T22 | ₹9.50/kWh | 80.64 kWh | ₹766 | ₹22,982 | ₹21,833 |
| XY-ANTMINER-L9-16G-T23 | ₹9.75/kWh | 80.64 kWh | ₹786 | ₹23,587 | ₹22,408 |
| XY-ANTMINER-L9-16G-T24 | ₹10.00/kWh | 80.64 kWh | ₹806 | ₹24,192 | ₹22,982 |
| XY-ANTMINER-L9-16G-T25 | ₹10.25/kWh | 80.64 kWh | ₹827 | ₹24,797 | ₹23,557 |
| XY-ANTMINER-L9-16G-T26 | ₹10.50/kWh | 80.64 kWh | ₹847 | ₹25,402 | ₹24,132 |
| XY-ANTMINER-L9-16G-T27 | ₹10.75/kWh | 80.64 kWh | ₹867 | ₹26,006 | ₹24,706 |
| XY-ANTMINER-L9-16G-T28 | ₹11.00/kWh | 80.64 kWh | ₹887 | ₹26,611 | ₹25,281 |
| XY-ANTMINER-L9-16G-T29 | ₹11.25/kWh | 80.64 kWh | ₹907 | ₹27,216 | ₹25,855 |
| XY-ANTMINER-L9-16G-T30 | ₹11.50/kWh | 80.64 kWh | ₹927 | ₹27,821 | ₹26,430 |
| XY-ANTMINER-L9-16G-T31 | ₹11.75/kWh | 80.64 kWh | ₹948 | ₹28,426 | ₹27,004 |
| XY-ANTMINER-L9-16G-T32 | ₹12.00/kWh | 80.64 kWh | ₹968 | ₹29,030 | ₹27,579 |
| XY-ANTMINER-L9-16G-T33 | ₹12.25/kWh | 80.64 kWh | ₹988 | ₹29,635 | ₹28,153 |
| XY-ANTMINER-L9-16G-T34 | ₹12.50/kWh | 80.64 kWh | ₹1,008 | ₹30,240 | ₹28,728 |
Reference series XY-ANTMINER-L9-16G-U uses ₹7.75/kWh and the 3,360W input to show how scheduled operating time changes energy. Revenue, difficulty and coin price are deliberately excluded.
| Worksheet ref. | Operating share | Monthly hours | Monthly energy | Electricity only | Illustrative tariff |
|---|---|---|---|---|---|
| XY-ANTMINER-L9-16G-U01 | 60% | 432 h | 1,451.52 kWh | ₹11,249 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U02 | 62% | 446.4 h | 1,499.9 kWh | ₹11,624 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U03 | 64% | 460.8 h | 1,548.29 kWh | ₹11,999 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U04 | 66% | 475.2 h | 1,596.67 kWh | ₹12,374 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U05 | 68% | 489.6 h | 1,645.06 kWh | ₹12,749 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U06 | 70% | 504 h | 1,693.44 kWh | ₹13,124 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U07 | 72% | 518.4 h | 1,741.82 kWh | ₹13,499 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U08 | 74% | 532.8 h | 1,790.21 kWh | ₹13,874 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U09 | 76% | 547.2 h | 1,838.59 kWh | ₹14,249 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U10 | 78% | 561.6 h | 1,886.98 kWh | ₹14,624 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U11 | 80% | 576 h | 1,935.36 kWh | ₹14,999 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U12 | 82% | 590.4 h | 1,983.74 kWh | ₹15,374 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U13 | 84% | 604.8 h | 2,032.13 kWh | ₹15,749 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U14 | 86% | 619.2 h | 2,080.51 kWh | ₹16,124 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U15 | 88% | 633.6 h | 2,128.9 kWh | ₹16,499 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U16 | 90% | 648 h | 2,177.28 kWh | ₹16,874 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U17 | 92% | 662.4 h | 2,225.66 kWh | ₹17,249 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U18 | 94% | 676.8 h | 2,274.05 kWh | ₹17,624 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U19 | 96% | 691.2 h | 2,322.43 kWh | ₹17,999 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U20 | 98% | 705.6 h | 2,370.82 kWh | ₹18,374 | ₹7.75/kWh |
| XY-ANTMINER-L9-16G-U21 | 100% | 720 h | 2,419.2 kWh | ₹18,749 | ₹7.75/kWh |
Reference series XY-ANTMINER-L9-16G-F scales catalogue load and heat for planning discussions. The 230V current is simple watts-divided-by-volts arithmetic and is not a circuit recommendation.
| Worksheet ref. | Units | Miner load | Arithmetic at 230V | Heat to remove | 30-day energy |
|---|---|---|---|---|---|
| XY-ANTMINER-L9-16G-F01 | 1 | 3.36 kW | 14.61 A | 11,464 BTU/h | 2,419.2 kWh |
| XY-ANTMINER-L9-16G-F02 | 2 | 6.72 kW | 29.22 A | 22,929 BTU/h | 4,838.4 kWh |
| XY-ANTMINER-L9-16G-F03 | 3 | 10.08 kW | 43.83 A | 34,393 BTU/h | 7,257.6 kWh |
| XY-ANTMINER-L9-16G-F04 | 4 | 13.44 kW | 58.43 A | 45,857 BTU/h | 9,676.8 kWh |
| XY-ANTMINER-L9-16G-F05 | 5 | 16.8 kW | 73.04 A | 57,322 BTU/h | 12,096 kWh |
| XY-ANTMINER-L9-16G-F06 | 6 | 20.16 kW | 87.65 A | 68,786 BTU/h | 14,515.2 kWh |
| XY-ANTMINER-L9-16G-F07 | 7 | 23.52 kW | 102.26 A | 80,250 BTU/h | 16,934.4 kWh |
| XY-ANTMINER-L9-16G-F08 | 8 | 26.88 kW | 116.87 A | 91,715 BTU/h | 19,353.6 kWh |
| XY-ANTMINER-L9-16G-F09 | 9 | 30.24 kW | 131.48 A | 103,179 BTU/h | 21,772.8 kWh |
| XY-ANTMINER-L9-16G-F10 | 10 | 33.6 kW | 146.09 A | 114,643 BTU/h | 24,192 kWh |
| XY-ANTMINER-L9-16G-F11 | 11 | 36.96 kW | 160.7 A | 126,108 BTU/h | 26,611.2 kWh |
| XY-ANTMINER-L9-16G-F12 | 12 | 40.32 kW | 175.3 A | 137,572 BTU/h | 29,030.4 kWh |
| XY-ANTMINER-L9-16G-F13 | 13 | 43.68 kW | 189.91 A | 149,036 BTU/h | 31,449.6 kWh |
| XY-ANTMINER-L9-16G-F14 | 14 | 47.04 kW | 204.52 A | 160,500 BTU/h | 33,868.8 kWh |
| XY-ANTMINER-L9-16G-F15 | 15 | 50.4 kW | 219.13 A | 171,965 BTU/h | 36,288 kWh |
| XY-ANTMINER-L9-16G-F16 | 16 | 53.76 kW | 233.74 A | 183,429 BTU/h | 38,707.2 kWh |
| XY-ANTMINER-L9-16G-F17 | 17 | 57.12 kW | 248.35 A | 194,893 BTU/h | 41,126.4 kWh |
| XY-ANTMINER-L9-16G-F18 | 18 | 60.48 kW | 262.96 A | 206,358 BTU/h | 43,545.6 kWh |
| XY-ANTMINER-L9-16G-F19 | 19 | 63.84 kW | 277.57 A | 217,822 BTU/h | 45,964.8 kWh |
| XY-ANTMINER-L9-16G-F20 | 20 | 67.2 kW | 292.17 A | 229,286 BTU/h | 48,384 kWh |
Log series XY-ANTMINER-L9-16G-L provides 48 half-hour observation references for a 24-hour Antminer L9 (16G) acceptance record. The load and heat columns are arithmetic sensitivity values around the published 3,360W input, not acceptable ranges or predicted readings. Enter actual dashboard and meter evidence beside the corresponding reference.
| Log ref. | Elapsed point | Sensitivity | Reference load | Reference energy | Heat equivalent | Observation focus |
|---|---|---|---|---|---|---|
| XY-ANTMINER-L9-16G-L001 | 0.5 hours | 90.030% reference | 3.03 kW | 1.51 kWh | 10,321 BTU/h | output |
| XY-ANTMINER-L9-16G-L002 | 1 hours | 90.103% reference | 3.03 kW | 3.03 kWh | 10,330 BTU/h | boards |
| XY-ANTMINER-L9-16G-L003 | 1.5 hours | 90.176% reference | 3.03 kW | 4.54 kWh | 10,338 BTU/h | thermal |
| XY-ANTMINER-L9-16G-L004 | 2 hours | 90.249% reference | 3.03 kW | 6.06 kWh | 10,346 BTU/h | cooling |
| XY-ANTMINER-L9-16G-L005 | 2.5 hours | 90.322% reference | 3.03 kW | 7.59 kWh | 10,355 BTU/h | network |
| XY-ANTMINER-L9-16G-L006 | 3 hours | 90.395% reference | 3.04 kW | 9.11 kWh | 10,363 BTU/h | alerts |
| XY-ANTMINER-L9-16G-L007 | 3.5 hours | 90.468% reference | 3.04 kW | 10.64 kWh | 10,372 BTU/h | connectors |
| XY-ANTMINER-L9-16G-L008 | 4 hours | 90.541% reference | 3.04 kW | 12.17 kWh | 10,380 BTU/h | firmware |
| XY-ANTMINER-L9-16G-L009 | 4.5 hours | 90.614% reference | 3.04 kW | 13.7 kWh | 10,388 BTU/h | notes |
| XY-ANTMINER-L9-16G-L010 | 5 hours | 90.687% reference | 3.05 kW | 15.24 kWh | 10,397 BTU/h | label |
| XY-ANTMINER-L9-16G-L011 | 5.5 hours | 90.760% reference | 3.05 kW | 16.77 kWh | 10,405 BTU/h | voltage |
| XY-ANTMINER-L9-16G-L012 | 6 hours | 90.833% reference | 3.05 kW | 18.31 kWh | 10,413 BTU/h | input |
| XY-ANTMINER-L9-16G-L013 | 6.5 hours | 90.906% reference | 3.05 kW | 19.85 kWh | 10,422 BTU/h | output |
| XY-ANTMINER-L9-16G-L014 | 7 hours | 90.979% reference | 3.06 kW | 21.4 kWh | 10,430 BTU/h | boards |
| XY-ANTMINER-L9-16G-L015 | 7.5 hours | 91.052% reference | 3.06 kW | 22.95 kWh | 10,438 BTU/h | thermal |
| XY-ANTMINER-L9-16G-L016 | 8 hours | 91.125% reference | 3.06 kW | 24.49 kWh | 10,447 BTU/h | cooling |
| XY-ANTMINER-L9-16G-L017 | 8.5 hours | 91.198% reference | 3.06 kW | 26.05 kWh | 10,455 BTU/h | network |
| XY-ANTMINER-L9-16G-L018 | 9 hours | 91.271% reference | 3.07 kW | 27.6 kWh | 10,464 BTU/h | alerts |
| XY-ANTMINER-L9-16G-L019 | 9.5 hours | 91.344% reference | 3.07 kW | 29.16 kWh | 10,472 BTU/h | connectors |
| XY-ANTMINER-L9-16G-L020 | 10 hours | 91.417% reference | 3.07 kW | 30.72 kWh | 10,480 BTU/h | firmware |
| XY-ANTMINER-L9-16G-L021 | 10.5 hours | 91.490% reference | 3.07 kW | 32.28 kWh | 10,489 BTU/h | notes |
| XY-ANTMINER-L9-16G-L022 | 11 hours | 91.563% reference | 3.08 kW | 33.84 kWh | 10,497 BTU/h | label |
| XY-ANTMINER-L9-16G-L023 | 11.5 hours | 91.636% reference | 3.08 kW | 35.41 kWh | 10,505 BTU/h | voltage |
| XY-ANTMINER-L9-16G-L024 | 12 hours | 91.709% reference | 3.08 kW | 36.98 kWh | 10,514 BTU/h | input |
| XY-ANTMINER-L9-16G-L025 | 12.5 hours | 91.782% reference | 3.08 kW | 38.55 kWh | 10,522 BTU/h | output |
| XY-ANTMINER-L9-16G-L026 | 13 hours | 91.855% reference | 3.09 kW | 40.12 kWh | 10,531 BTU/h | boards |
| XY-ANTMINER-L9-16G-L027 | 13.5 hours | 91.928% reference | 3.09 kW | 41.7 kWh | 10,539 BTU/h | thermal |
| XY-ANTMINER-L9-16G-L028 | 14 hours | 92.001% reference | 3.09 kW | 43.28 kWh | 10,547 BTU/h | cooling |
| XY-ANTMINER-L9-16G-L029 | 14.5 hours | 92.074% reference | 3.09 kW | 44.86 kWh | 10,556 BTU/h | network |
| XY-ANTMINER-L9-16G-L030 | 15 hours | 92.147% reference | 3.1 kW | 46.44 kWh | 10,564 BTU/h | alerts |
| XY-ANTMINER-L9-16G-L031 | 15.5 hours | 92.220% reference | 3.1 kW | 48.03 kWh | 10,572 BTU/h | connectors |
| XY-ANTMINER-L9-16G-L032 | 16 hours | 92.293% reference | 3.1 kW | 49.62 kWh | 10,581 BTU/h | firmware |
| XY-ANTMINER-L9-16G-L033 | 16.5 hours | 92.366% reference | 3.1 kW | 51.21 kWh | 10,589 BTU/h | notes |
| XY-ANTMINER-L9-16G-L034 | 17 hours | 92.439% reference | 3.11 kW | 52.8 kWh | 10,598 BTU/h | label |
| XY-ANTMINER-L9-16G-L035 | 17.5 hours | 92.512% reference | 3.11 kW | 54.4 kWh | 10,606 BTU/h | voltage |
| XY-ANTMINER-L9-16G-L036 | 18 hours | 92.585% reference | 3.11 kW | 56 kWh | 10,614 BTU/h | input |
| XY-ANTMINER-L9-16G-L037 | 18.5 hours | 92.658% reference | 3.11 kW | 57.6 kWh | 10,623 BTU/h | output |
| XY-ANTMINER-L9-16G-L038 | 19 hours | 92.731% reference | 3.12 kW | 59.2 kWh | 10,631 BTU/h | boards |
| XY-ANTMINER-L9-16G-L039 | 19.5 hours | 92.804% reference | 3.12 kW | 60.81 kWh | 10,639 BTU/h | thermal |
| XY-ANTMINER-L9-16G-L040 | 20 hours | 92.877% reference | 3.12 kW | 62.41 kWh | 10,648 BTU/h | cooling |
| XY-ANTMINER-L9-16G-L041 | 20.5 hours | 92.950% reference | 3.12 kW | 64.02 kWh | 10,656 BTU/h | network |
| XY-ANTMINER-L9-16G-L042 | 21 hours | 93.023% reference | 3.13 kW | 65.64 kWh | 10,664 BTU/h | alerts |
| XY-ANTMINER-L9-16G-L043 | 21.5 hours | 93.096% reference | 3.13 kW | 67.25 kWh | 10,673 BTU/h | connectors |
| XY-ANTMINER-L9-16G-L044 | 22 hours | 93.169% reference | 3.13 kW | 68.87 kWh | 10,681 BTU/h | firmware |
| XY-ANTMINER-L9-16G-L045 | 22.5 hours | 93.242% reference | 3.13 kW | 70.49 kWh | 10,690 BTU/h | notes |
| XY-ANTMINER-L9-16G-L046 | 23 hours | 93.315% reference | 3.14 kW | 72.11 kWh | 10,698 BTU/h | label |
| XY-ANTMINER-L9-16G-L047 | 23.5 hours | 93.388% reference | 3.14 kW | 73.74 kWh | 10,706 BTU/h | voltage |
| XY-ANTMINER-L9-16G-L048 | 24 hours | 93.461% reference | 3.14 kW | 75.37 kWh | 10,715 BTU/h | input |