📣 Best Rates to "Buy BTC Miner" & "ASIC Miner India" Hardware 🚚 Same-Day Shipping on In-Stock Units • Express Delivery 4–6 Days 🔔 Live BTC: ₹77,79,248
LTC+DOGE
Antminer L7 (9050M) Bitcoin Miner Price India - XYZ Mining
Confirm Condition
Confirm Warranty
GST Invoice
Pan-India Delivery

Bitmain

Antminer L7 (9050M)

Standard Model

Est. Daily Income

Calculating...

Based on Live BTC

Hashrate

9050

MH/s

Power

3260W

Consumption

Monthly

2347

Units (kWh)

Catalogue Price

₹1,20,000

*Confirm live price, GST treatment and stock

Exact listing profile

Antminer L7 (9050M) specifications at a glance

These fields come from the current XYZ Mining Shop catalogue. Confirm the offered machine’s label and measured values before purchase.

Hashrate

9.05 GH/s

Algorithm

Scrypt

Power

3,260W

Cooling

Air

Monthly energy

2,347.2 kWh

Catalogue status

Catalogue listing available

Model decision

The operating case for this exact bin

The operating case begins with 9.05 GH/s and 3,260W. It suits a prepared Scrypt deployment comparing Litecoin/Dogecoin merged-mining output against electricity and ventilation cost.

High continuous load

At this power level a normal household outlet should not be assumed suitable. Ask a qualified electrician to assess sanctioned load, cable size, breaker rating, earthing and connector temperature under continuous operation.

Calculated monthly site load

At the listed 3,260W, continuous operation is approximately 2,347.2 kWh per 30-day month before cooling overhead. Nominal current is about 14.17A at 230V, and the room or liquid loop must reject roughly 11,123.12 BTU/hour of heat. Actual wall draw varies by batch, firmware, voltage and ambient conditions.

Forced-air cooling

Plan a clean intake and a direct hot-air exhaust so discharged heat cannot recirculate. Fan noise and airflow rise with ambient temperature; choose the room and ducting before delivery.

Brand and batch verification

For a Bitmain quotation, match the complete Antminer model, hashrate bin, serial and cooling version. Family names alone are not enough because adjacent variants can use different operating profiles.

Same-algorithm efficiency check

Using the catalogue figures, the simple power-to-hash ratio is about 360.22 W per GH/s. Use this only to compare machines working on the same Scrypt workload.

Model-specific worksheet

A measurable input sheet for Antminer L7 (9050M)

This worksheet converts Antminer L7 (9050M) from a product name into auditable inputs. The current entry is 9.05 GH/s and 3,260W; within its algorithm group it occupies hashrate position 3 of 11. Against Antminer L7 (8800M), this listing provides 2.84% more hashrate with 0W more nominal power and a ₹5,000 higher catalogue price. Antminer L7 (9300M), the next higher-hashrate entry, adds 2.76% hashrate while changing nominal power by 0W upward; its catalogue price is ₹5,000 higher.

Catalogue rank

3 of 11 by hashrate

Price intensity

₹13,260 per GH/s

Efficiency input

360.22 W/GH/s

24-hour energy

78.24 kWh

What one specification means on the meter

The machine converts almost all consumed electrical power into heat. The listed draw corresponds to roughly 11,123.12 BTU/hour per unit, or 33,369.36 BTU/hour for three. A air deployment must reject that heat without returning it to the intake or coolant loop.

One, three and five-unit load

FleetNominal load30-day energyCurrent at 230V*Heat output
1 unit3.26kW2,347.2 kWh14.17A11,123.12 BTU/h
3 units9.78kW7,041.6 kWh42.52A33,369.36 BTU/h
5 units16.3kW11,736 kWh70.87A55,615.6 BTU/h

Electricity-only sensitivity

All-in tariff1 unit/month3 units/month5 units/month
₹4/kWh₹9,389₹28,166₹46,944
₹6/kWh₹14,083₹42,250₹70,416
₹8/kWh₹18,778₹56,333₹93,888
₹10/kWh₹23,472₹70,416₹1,17,360

Antminer L7 (9050M) evidence checklist

Use these checks for this quotation instead of relying on copied family specifications.

  • Photograph the complete Antminer L7 (9050M) model label and serial before dispatch.
  • List every included PSU, adapter, cable, manifold or cooling accessory.
  • Ask for dashboard or test evidence that shows the 9.05 GH/s bin.
  • Verify packaging, insurance responsibility and the estimated dispatch date.
  • Confirm pool, wallet and firmware compatibility through current official sources.

*Current is simple watts ÷ 230V arithmetic. It is not electrical-design advice and does not include power factor, inrush, derating or cooling auxiliaries.

Purchase check

What a legitimate Antminer L7 (9050M) quotation should state

  • Complete model and 9.05 GH/s bin
  • New, used or refurbished condition
  • Included PSU, adapter, cables or cooling hardware
  • Serial/batch evidence and applicable warranty status
  • GST treatment, beneficiary details and dispatch timing
  • Written confirmation of current catalogue listing available

Range position

Compare Antminer L7 (9050M) with its nearest alternatives

Use a three-column decision: acquisition cost, monthly site cost and deployment complexity. Antminer L7 (8800M) sits below it at 8.8 GH/s; Antminer L7 (9300M) is the next higher comparison at 9.3 GH/s. The right choice is the one that improves the buyer’s constraint—not automatically the model with the largest number.

ModelHashratePowerCatalogue position
Antminer L7 (8800M)8.8 GH/s3,260W₹1,15,000
Antminer L7 (9050M)9.05 GH/s3,260W₹1,20,000
Antminer L7 (9300M)9.3 GH/s3,260W₹1,25,000

Model-specific answers

Antminer L7 (9050M) FAQs

Each answer is tied to this model’s catalogue position, calculated load or verification path.

Where does Antminer L7 (9050M) rank in the current catalogue?

Antminer L7 (9050M) is position 3 of 11 when current Scrypt entries are ordered from lower to higher hashrate. Ranking by hashrate alone does not account for efficiency, price or site fit.

What does a three-unit Antminer L7 (9050M) setup require?

Three units total 9.78kW nominal IT load and about 7,041.6 kWh per 30-day month before cooling overhead. Have the distribution and air system assessed for the combined load.

How should Antminer L7 (9050M) heat be planned?

The listed load becomes roughly 11,123.12 BTU/hour of continuous heat per unit. The air system must reject it without recirculation or uncontrolled coolant temperature.

What uptime should be assumed for Antminer L7 (9050M)?

Use several scenarios rather than a guaranteed figure. The worksheet includes 95%, 98% and always-on energy cases; actual uptime depends on power, network, pool, firmware and maintenance.

How does Antminer L7 (9050M) compare with the nearest catalogue model?

Against Antminer L7 (8800M), this listing provides 2.84% more hashrate with 0W more nominal power and a ₹5,000 higher catalogue price. Antminer L7 (9300M), the next higher-hashrate entry, adds 2.76% hashrate while changing nominal power by 0W upward; its catalogue price is ₹5,000 higher.

Same-algorithm options

Related machines to evaluate

Mining income is variable and is not guaranteed. Verify network data, electricity tariff, pool terms, product condition, specifications and the dated quotation independently.

MODEL-SPECIFIC PLANNING WORKSHEET · XY-ANTMINER-L7-9050M

A dated planning record for Antminer L7 (9050M)

The worksheet below is built from this product entry. It exposes each assumption so a buyer can replace catalogue inputs with quotation and meter evidence instead of treating estimates as guarantees.

XY-ANTMINER-L7-9050M identity

Worksheet XY-ANTMINER-L7-9050M applies only to Antminer L7 (9050M), the 9.05 GH/s Scrypt entry shown on this page. Its calculations begin with 3,260W catalogue input and air cooling; they must be replaced by a dated meter reading if the delivered batch behaves differently.

XY-ANTMINER-L7-9050M commercial boundary

The displayed Bitmain hardware figure is ₹1,20,000. Reference XY-ANTMINER-L7-9050M keeps that acquisition amount separate from GST treatment, freight, wiring, external heat rejection, pool fees and service work, all of which depend on the quotation or receiving site.

XY-ANTMINER-L7-9050M calculation boundary

Every XY-ANTMINER-L7-9050M value below is arithmetic, not a profitability forecast or electrical-design instruction. A qualified electrician must size conductors and protection for the complete installation, and network output must be evaluated with current third-party data.

Antminer L7 (9050M) electricity tariff matrix

Reference series XY-ANTMINER-L7-9050M-T holds 78.24 kWh per day constant and changes only the electricity tariff. The 95% column is a sensitivity case, not promised availability.

Worksheet ref.TariffNominal daily energyDaily electricity30-day electricity30-day at 95%
XY-ANTMINER-L7-9050M-T01₹4.25/kWh78.24 kWh₹333₹9,976₹9,477
XY-ANTMINER-L7-9050M-T02₹4.50/kWh78.24 kWh₹352₹10,562₹10,034
XY-ANTMINER-L7-9050M-T03₹4.75/kWh78.24 kWh₹372₹11,149₹10,592
XY-ANTMINER-L7-9050M-T04₹5.00/kWh78.24 kWh₹391₹11,736₹11,149
XY-ANTMINER-L7-9050M-T05₹5.25/kWh78.24 kWh₹411₹12,323₹11,707
XY-ANTMINER-L7-9050M-T06₹5.50/kWh78.24 kWh₹430₹12,910₹12,264
XY-ANTMINER-L7-9050M-T07₹5.75/kWh78.24 kWh₹450₹13,496₹12,822
XY-ANTMINER-L7-9050M-T08₹6.00/kWh78.24 kWh₹469₹14,083₹13,379
XY-ANTMINER-L7-9050M-T09₹6.25/kWh78.24 kWh₹489₹14,670₹13,936
XY-ANTMINER-L7-9050M-T10₹6.50/kWh78.24 kWh₹509₹15,257₹14,494
XY-ANTMINER-L7-9050M-T11₹6.75/kWh78.24 kWh₹528₹15,844₹15,051
XY-ANTMINER-L7-9050M-T12₹7.00/kWh78.24 kWh₹548₹16,430₹15,609
XY-ANTMINER-L7-9050M-T13₹7.25/kWh78.24 kWh₹567₹17,017₹16,166
XY-ANTMINER-L7-9050M-T14₹7.50/kWh78.24 kWh₹587₹17,604₹16,724
XY-ANTMINER-L7-9050M-T15₹7.75/kWh78.24 kWh₹606₹18,191₹17,281
XY-ANTMINER-L7-9050M-T16₹8.00/kWh78.24 kWh₹626₹18,778₹17,839
XY-ANTMINER-L7-9050M-T17₹8.25/kWh78.24 kWh₹645₹19,364₹18,396
XY-ANTMINER-L7-9050M-T18₹8.50/kWh78.24 kWh₹665₹19,951₹18,954
XY-ANTMINER-L7-9050M-T19₹8.75/kWh78.24 kWh₹685₹20,538₹19,511
XY-ANTMINER-L7-9050M-T20₹9.00/kWh78.24 kWh₹704₹21,125₹20,069
XY-ANTMINER-L7-9050M-T21₹9.25/kWh78.24 kWh₹724₹21,712₹20,626
XY-ANTMINER-L7-9050M-T22₹9.50/kWh78.24 kWh₹743₹22,298₹21,183
XY-ANTMINER-L7-9050M-T23₹9.75/kWh78.24 kWh₹763₹22,885₹21,741
XY-ANTMINER-L7-9050M-T24₹10.00/kWh78.24 kWh₹782₹23,472₹22,298
XY-ANTMINER-L7-9050M-T25₹10.25/kWh78.24 kWh₹802₹24,059₹22,856
XY-ANTMINER-L7-9050M-T26₹10.50/kWh78.24 kWh₹822₹24,646₹23,413
XY-ANTMINER-L7-9050M-T27₹10.75/kWh78.24 kWh₹841₹25,232₹23,971
XY-ANTMINER-L7-9050M-T28₹11.00/kWh78.24 kWh₹861₹25,819₹24,528
XY-ANTMINER-L7-9050M-T29₹11.25/kWh78.24 kWh₹880₹26,406₹25,086
XY-ANTMINER-L7-9050M-T30₹11.50/kWh78.24 kWh₹900₹26,993₹25,643
XY-ANTMINER-L7-9050M-T31₹11.75/kWh78.24 kWh₹919₹27,580₹26,201
XY-ANTMINER-L7-9050M-T32₹12.00/kWh78.24 kWh₹939₹28,166₹26,758
XY-ANTMINER-L7-9050M-T33₹12.25/kWh78.24 kWh₹958₹28,753₹27,316
XY-ANTMINER-L7-9050M-T34₹12.50/kWh78.24 kWh₹978₹29,340₹27,873

Antminer L7 (9050M) operating-window matrix

Reference series XY-ANTMINER-L7-9050M-U uses ₹6.25/kWh and the 3,260W input to show how scheduled operating time changes energy. Revenue, difficulty and coin price are deliberately excluded.

Worksheet ref.Operating shareMonthly hoursMonthly energyElectricity onlyIllustrative tariff
XY-ANTMINER-L7-9050M-U0160%432 h1,408.32 kWh₹8,802₹6.25/kWh
XY-ANTMINER-L7-9050M-U0262%446.4 h1,455.26 kWh₹9,095₹6.25/kWh
XY-ANTMINER-L7-9050M-U0364%460.8 h1,502.21 kWh₹9,389₹6.25/kWh
XY-ANTMINER-L7-9050M-U0466%475.2 h1,549.15 kWh₹9,682₹6.25/kWh
XY-ANTMINER-L7-9050M-U0568%489.6 h1,596.1 kWh₹9,976₹6.25/kWh
XY-ANTMINER-L7-9050M-U0670%504 h1,643.04 kWh₹10,269₹6.25/kWh
XY-ANTMINER-L7-9050M-U0772%518.4 h1,689.98 kWh₹10,562₹6.25/kWh
XY-ANTMINER-L7-9050M-U0874%532.8 h1,736.93 kWh₹10,856₹6.25/kWh
XY-ANTMINER-L7-9050M-U0976%547.2 h1,783.87 kWh₹11,149₹6.25/kWh
XY-ANTMINER-L7-9050M-U1078%561.6 h1,830.82 kWh₹11,443₹6.25/kWh
XY-ANTMINER-L7-9050M-U1180%576 h1,877.76 kWh₹11,736₹6.25/kWh
XY-ANTMINER-L7-9050M-U1282%590.4 h1,924.7 kWh₹12,029₹6.25/kWh
XY-ANTMINER-L7-9050M-U1384%604.8 h1,971.65 kWh₹12,323₹6.25/kWh
XY-ANTMINER-L7-9050M-U1486%619.2 h2,018.59 kWh₹12,616₹6.25/kWh
XY-ANTMINER-L7-9050M-U1588%633.6 h2,065.54 kWh₹12,910₹6.25/kWh
XY-ANTMINER-L7-9050M-U1690%648 h2,112.48 kWh₹13,203₹6.25/kWh
XY-ANTMINER-L7-9050M-U1792%662.4 h2,159.42 kWh₹13,496₹6.25/kWh
XY-ANTMINER-L7-9050M-U1894%676.8 h2,206.37 kWh₹13,790₹6.25/kWh
XY-ANTMINER-L7-9050M-U1996%691.2 h2,253.31 kWh₹14,083₹6.25/kWh
XY-ANTMINER-L7-9050M-U2098%705.6 h2,300.26 kWh₹14,377₹6.25/kWh
XY-ANTMINER-L7-9050M-U21100%720 h2,347.2 kWh₹14,670₹6.25/kWh

Antminer L7 (9050M) fleet-load matrix

Reference series XY-ANTMINER-L7-9050M-F scales catalogue load and heat for planning discussions. The 230V current is simple watts-divided-by-volts arithmetic and is not a circuit recommendation.

Worksheet ref.UnitsMiner loadArithmetic at 230VHeat to remove30-day energy
XY-ANTMINER-L7-9050M-F0113.26 kW14.17 A11,123 BTU/h2,347.2 kWh
XY-ANTMINER-L7-9050M-F0226.52 kW28.35 A22,246 BTU/h4,694.4 kWh
XY-ANTMINER-L7-9050M-F0339.78 kW42.52 A33,369 BTU/h7,041.6 kWh
XY-ANTMINER-L7-9050M-F04413.04 kW56.7 A44,492 BTU/h9,388.8 kWh
XY-ANTMINER-L7-9050M-F05516.3 kW70.87 A55,616 BTU/h11,736 kWh
XY-ANTMINER-L7-9050M-F06619.56 kW85.04 A66,739 BTU/h14,083.2 kWh
XY-ANTMINER-L7-9050M-F07722.82 kW99.22 A77,862 BTU/h16,430.4 kWh
XY-ANTMINER-L7-9050M-F08826.08 kW113.39 A88,985 BTU/h18,777.6 kWh
XY-ANTMINER-L7-9050M-F09929.34 kW127.57 A100,108 BTU/h21,124.8 kWh
XY-ANTMINER-L7-9050M-F101032.6 kW141.74 A111,231 BTU/h23,472 kWh
XY-ANTMINER-L7-9050M-F111135.86 kW155.91 A122,354 BTU/h25,819.2 kWh
XY-ANTMINER-L7-9050M-F121239.12 kW170.09 A133,477 BTU/h28,166.4 kWh
XY-ANTMINER-L7-9050M-F131342.38 kW184.26 A144,601 BTU/h30,513.6 kWh
XY-ANTMINER-L7-9050M-F141445.64 kW198.43 A155,724 BTU/h32,860.8 kWh
XY-ANTMINER-L7-9050M-F151548.9 kW212.61 A166,847 BTU/h35,208 kWh
XY-ANTMINER-L7-9050M-F161652.16 kW226.78 A177,970 BTU/h37,555.2 kWh
XY-ANTMINER-L7-9050M-F171755.42 kW240.96 A189,093 BTU/h39,902.4 kWh
XY-ANTMINER-L7-9050M-F181858.68 kW255.13 A200,216 BTU/h42,249.6 kWh
XY-ANTMINER-L7-9050M-F191961.94 kW269.3 A211,339 BTU/h44,596.8 kWh
XY-ANTMINER-L7-9050M-F202065.2 kW283.48 A222,462 BTU/h46,944 kWh
MODEL-SPECIFIC COMMISSIONING LOG · XY-ANTMINER-L7-9050M

Log series XY-ANTMINER-L7-9050M-L provides 48 half-hour observation references for a 24-hour Antminer L7 (9050M) acceptance record. The load and heat columns are arithmetic sensitivity values around the published 3,260W input, not acceptable ranges or predicted readings. Enter actual dashboard and meter evidence beside the corresponding reference.

Log ref.Elapsed pointSensitivityReference loadReference energyHeat equivalentObservation focus
XY-ANTMINER-L7-9050M-L0010.5 hours89.484% reference2.92 kW1.46 kWh9,953 BTU/hconnectors
XY-ANTMINER-L7-9050M-L0021 hours89.557% reference2.92 kW2.92 kWh9,962 BTU/hfirmware
XY-ANTMINER-L7-9050M-L0031.5 hours89.630% reference2.92 kW4.38 kWh9,970 BTU/hnotes
XY-ANTMINER-L7-9050M-L0042 hours89.703% reference2.92 kW5.85 kWh9,978 BTU/hlabel
XY-ANTMINER-L7-9050M-L0052.5 hours89.776% reference2.93 kW7.32 kWh9,986 BTU/hvoltage
XY-ANTMINER-L7-9050M-L0063 hours89.849% reference2.93 kW8.79 kWh9,994 BTU/hinput
XY-ANTMINER-L7-9050M-L0073.5 hours89.922% reference2.93 kW10.26 kWh10,002 BTU/houtput
XY-ANTMINER-L7-9050M-L0084 hours89.995% reference2.93 kW11.74 kWh10,010 BTU/hboards
XY-ANTMINER-L7-9050M-L0094.5 hours90.068% reference2.94 kW13.21 kWh10,018 BTU/hthermal
XY-ANTMINER-L7-9050M-L0105 hours90.141% reference2.94 kW14.69 kWh10,026 BTU/hcooling
XY-ANTMINER-L7-9050M-L0115.5 hours90.214% reference2.94 kW16.18 kWh10,035 BTU/hnetwork
XY-ANTMINER-L7-9050M-L0126 hours90.287% reference2.94 kW17.66 kWh10,043 BTU/halerts
XY-ANTMINER-L7-9050M-L0136.5 hours90.360% reference2.95 kW19.15 kWh10,051 BTU/hconnectors
XY-ANTMINER-L7-9050M-L0147 hours90.433% reference2.95 kW20.64 kWh10,059 BTU/hfirmware
XY-ANTMINER-L7-9050M-L0157.5 hours90.506% reference2.95 kW22.13 kWh10,067 BTU/hnotes
XY-ANTMINER-L7-9050M-L0168 hours90.579% reference2.95 kW23.62 kWh10,075 BTU/hlabel
XY-ANTMINER-L7-9050M-L0178.5 hours90.652% reference2.96 kW25.12 kWh10,083 BTU/hvoltage
XY-ANTMINER-L7-9050M-L0189 hours90.725% reference2.96 kW26.62 kWh10,091 BTU/hinput
XY-ANTMINER-L7-9050M-L0199.5 hours90.798% reference2.96 kW28.12 kWh10,100 BTU/houtput
XY-ANTMINER-L7-9050M-L02010 hours90.871% reference2.96 kW29.62 kWh10,108 BTU/hboards
XY-ANTMINER-L7-9050M-L02110.5 hours90.944% reference2.96 kW31.13 kWh10,116 BTU/hthermal
XY-ANTMINER-L7-9050M-L02211 hours91.017% reference2.97 kW32.64 kWh10,124 BTU/hcooling
XY-ANTMINER-L7-9050M-L02311.5 hours91.090% reference2.97 kW34.15 kWh10,132 BTU/hnetwork
XY-ANTMINER-L7-9050M-L02412 hours91.163% reference2.97 kW35.66 kWh10,140 BTU/halerts
XY-ANTMINER-L7-9050M-L02512.5 hours91.236% reference2.97 kW37.18 kWh10,148 BTU/hconnectors
XY-ANTMINER-L7-9050M-L02613 hours91.309% reference2.98 kW38.7 kWh10,156 BTU/hfirmware
XY-ANTMINER-L7-9050M-L02713.5 hours91.382% reference2.98 kW40.22 kWh10,165 BTU/hnotes
XY-ANTMINER-L7-9050M-L02814 hours91.455% reference2.98 kW41.74 kWh10,173 BTU/hlabel
XY-ANTMINER-L7-9050M-L02914.5 hours91.528% reference2.98 kW43.27 kWh10,181 BTU/hvoltage
XY-ANTMINER-L7-9050M-L03015 hours91.601% reference2.99 kW44.79 kWh10,189 BTU/hinput
XY-ANTMINER-L7-9050M-L03115.5 hours91.674% reference2.99 kW46.32 kWh10,197 BTU/houtput
XY-ANTMINER-L7-9050M-L03216 hours91.747% reference2.99 kW47.86 kWh10,205 BTU/hboards
XY-ANTMINER-L7-9050M-L03316.5 hours91.820% reference2.99 kW49.39 kWh10,213 BTU/hthermal
XY-ANTMINER-L7-9050M-L03417 hours91.893% reference3 kW50.93 kWh10,221 BTU/hcooling
XY-ANTMINER-L7-9050M-L03517.5 hours91.966% reference3 kW52.47 kWh10,229 BTU/hnetwork
XY-ANTMINER-L7-9050M-L03618 hours92.039% reference3 kW54.01 kWh10,238 BTU/halerts
XY-ANTMINER-L7-9050M-L03718.5 hours92.112% reference3 kW55.55 kWh10,246 BTU/hconnectors
XY-ANTMINER-L7-9050M-L03819 hours92.185% reference3.01 kW57.1 kWh10,254 BTU/hfirmware
XY-ANTMINER-L7-9050M-L03919.5 hours92.258% reference3.01 kW58.65 kWh10,262 BTU/hnotes
XY-ANTMINER-L7-9050M-L04020 hours92.331% reference3.01 kW60.2 kWh10,270 BTU/hlabel
XY-ANTMINER-L7-9050M-L04120.5 hours92.404% reference3.01 kW61.75 kWh10,278 BTU/hvoltage
XY-ANTMINER-L7-9050M-L04221 hours92.477% reference3.01 kW63.31 kWh10,286 BTU/hinput
XY-ANTMINER-L7-9050M-L04321.5 hours92.550% reference3.02 kW64.87 kWh10,294 BTU/houtput
XY-ANTMINER-L7-9050M-L04422 hours92.623% reference3.02 kW66.43 kWh10,303 BTU/hboards
XY-ANTMINER-L7-9050M-L04522.5 hours92.696% reference3.02 kW67.99 kWh10,311 BTU/hthermal
XY-ANTMINER-L7-9050M-L04623 hours92.769% reference3.02 kW69.56 kWh10,319 BTU/hcooling
XY-ANTMINER-L7-9050M-L04723.5 hours92.842% reference3.03 kW71.13 kWh10,327 BTU/hnetwork
XY-ANTMINER-L7-9050M-L04824 hours92.915% reference3.03 kW72.7 kWh10,335 BTU/halerts